HomeNon-metal Hot cabinets with forced air circulation up to 300°C
Hot cabinets with forced air circulation up to 300°C
Our true all-rounder: It has a virtually unlimited capacity and is at the same time particularly adaptable to the specific requirements of a large variety of testing applications. The enhanced timer functions and the digitally controlled air turbine may be used to perfectly control temperature parameters and air circulation conditions.
Performance features/Equipment:
■ Electronically controlled APT.Iine™ preheating chamber technology ■ Temperature range of 5 °C above ambient temperature up to 300 °C ■ MS Controller with several timer functions ■ Controller timer functions: delayed ON, delayed OFF and temperature-dependent delayed OFF ■ Digital temperature setting accurate to the degree ■ Adjustable ramp function ■ Adjustable fan speed (from 0 to100 %) ■ Adjustable temperature limiter class 2 (DIN 12880) with visual temperature alarm ■ Adjustable air renewal by means of air flaps at the front and exhaust pipe Ø 50 mm at the rear ■ RS 422 interface for communication software APT-COM™ Data Control System or switch over to printer output with RS 232 / RS 422 interface converter ■ Adjustable intervals for printer ■ Units up to 115 liters are stackable ■ 2 chrome-plated drawers
The series FP realizes the most demanding test applications and is particularly effective, due to the extensive programming options. The forced air circulation reliably provides short drying times as well as extra rapid heating-up - also and even with fully loaded chambers.
Additional functions series FP compared to series FED: ■ MP controller ■ Program control (1 program with 20 sections, switchable to 2 programs with 10 sections each) ■ The time intervals of the program sections can be adjusted up to a maximum of 99.59 h or 999,59 h ■ Adjustable fan speed for higher dynamics ■ Integrated weekly timer with real-time function
1) without window 2) Up to 93 % of the set value 3) The air renewal is depending on the inner chamber and on the ambient temperature and is subject to a high individual variance. The indicated air exchange rates correspond to average values for standard devices. Individual air exchange measurements according to ASTM D5374 are optionally available.
All technical data exclusively apply for devices with standard type operating at an ambient temperature of 25 °C and a main voltage fluctuation of ± 10 %. These temperature values are determined in accordance with the factory standard referring to DIN 12880, part 2 and are based on the recommended wall clearances amounting to 10 % of the height, width and depth of the inner chamber. For serial devices all indications are average values. We reserve the right to make technical alteration.