Business area I: Industry/Metal
Metal
Business area II: Industry/Non-Metal
Non-metal
Business area III: Ceramic art
Arts & Crafts
Home arrow Non-metal arrow Series FD - Drying cabinets with with natural air circulation or forced air circulation up to 300°C
Series FD - Drying cabinets with with natural air circulation or forced air circulation up to 300°C Print


Modell ED / FD

 ED Serie

Drying cabinets ED series - drying cabinets with natural air circulation

Routine drying and sterilization applications up to 300 °C and precisely controlled elevated temperatures are the strengths of ED drying cabinets: Due to the natural air circulation with a high rate of air exchange, thermal processes run with significantly increased efficiency.





Drying cabinets series FD - drying cabinets with forced air circulation
FD series units are primarily used in applications needing especially rapid drying and sterilization. With a totally homogenous temperature distribution, rapid dynamic response and our specially developed air turbine with a higher output of 20%, the FD is saving useful time.





 FD Serie

 
Electronically controlled APT.Iine™ preheating chamber technology
Temperature range of 5 °C above ambient temperature up to 300 °C
DS controller with integrated timer from 0 to99h
Digital temperature setting to the degree
Adjustable ramp function
Adjustable temperature limiter class 2 (DIN 12880) with visual temperature alarm
■ Adjustable air renewal by means of air flaps at the front and exhaust pipe Ø 50 mm at the rear
Optionally with or without interface RS 422 for communication software APT-COM™ DataControlSystem
 Units up to 115 liters are stackable
 2 chrome-plated drawers
 Binder
1) without window   2) Up to 93 % ofthe set value    3) The air renewal is depending on the inner chamber and on
the ambient temperature and is subject to a high individual variance. The indicated air exchange rates correspond
to average values for standard devices. Individual air exchange measurements according to ASTM D5374 are
optionally available.

All technical data exclusively apply for devices with standard type operating at an ambient temperature of 25 °C and a main voltage fluctuation of ± 10 %. These temperature values are determined in accordance with the factory standard referring to DIN 12880, part 2 and are based on the recommended wall clearances amounting to 10 % of the height, width and depth of the inner chamber. For serial devices all indications are average values. We reserve the right to make technical alteration.